This option allows you to specify an Associate Library Name, Cell Name or Instance Name for a guard ring.
This topic shows you how to use the Project Editor to configure those options.
- To launch the Animate Project Editor, on the command line enter:
animate_project_editor
- Expand the Animate section.
- Expand the Project section.
- Right-click on Project to launch a menu.
Select “Add Constraint Defaults”. - Right-click on Constraint Defaults.
Left-click on Add Guard Ring Association. - You can now set up the guard ring association options you require.
Associate
Library Name
Cell Name
or
Instance Name
Configuration
Add Element
Guard Ring Name
Terminal Name
Net Name (optional) - Right-click on Association.
Left-click on Add Cell. - To Add Terminal Name:
Double-click under Value next to Name, and enter a terminal name in the text field.
Click outside the text entry field.
This is now the minimum information needed to associate a guard ring to a cell. - Click the Validate and Save button to save your project settings.
The minimum required elements to configure are:
- Library Name
- Cell Name
- MPP Name
- Terminal Name or Net Name